Q:
How can I determine the flow rate of the pump I have?
A:
Flow rate is dependent on factors such as product viscosity, distance
pulled, distance pushed, and head pressure. The actual flow rate can
easily be determined by dispensing product into a beaker or measuring
cup and timing the feed. Knight pumps are generally rated by the number
of ounces per minute.
Q:
What is the maximum pressure that a peristaltic pump can push against?
A:
30 PSI max. Push capability decreases if squeeze tube is worn.
Q:
How can I get into a dispenser without knowing the access code?
A:
First check with the previous user, or with the original owner if
the equipment has changed hands. If its not possible to get the access
code using this approach, call Knight for assistance (be sure to have
the serial number of the unit available for verification).
Q:
Which squeeze tube goes with each pump?
A:
This correlates to the head size, or "series", that the
pump belongs to. The following specs are only the most common tube
sizes used. Other sizes may be available for special configurations.
- 500
Series uses T-51, T-53, T-50, T-66
- 800
Series uses T-50, T-66
- 900
Series uses T-86
Q:
What color roller goes with which squeeze tube?
A:
Again, this is based on head size, or "series" and the following
specs are shown in reference to the question about squeeze tubes.
- 500
Series: T-51 (brown), T-53 (blue), T-50 (yellow), T-66 (yellow)
- 800
Series: T-50 (yellow), T-66 (yellow)
- 900
Series: T-86 (white)